r/pools • u/Key-Ad2680 • 3h ago
Got sick of looking at crappy job by pool plumber a month back so I re-plumbed my pad. Looking forward to criticism :)
I've been just angry about the job the pool plumber did a month back. Yes, everything functioned but it went over the allotted space I need the equipment in (he claimed it is not possible) and just looked weirdly spaced out. Took me 2x12 hour days to redo (granted half of that time was just staring at the equipment to figure out wtf needs to be done to get this compacted. I still have no idea why he divided the spa suction and pool suction like he did.
Combined spa and pool suction instead of creating that ring around the planter. Added a gasket union to make future repairs easy and not have to cut more pipe down.
Removed the stupid check valve in front of the pump. He told me this CV is necessary but I did a test with the flapper inside removed and vacuum held pressure + I would rather know if I have a leak that breaks vacuum).
Turned filter so that inlet and outlet face north/south to create space on left and right side so to compact further.
Changed nipple on Jandy heater's gas line from to get another 4" inches of space. The exhaust still sits 7" inches from the wall so I think it's okay.
Replaced almost all 90 elbows elbows needed for the sections replaced with sweep elbows and still left a good 8" inches of straight pipe entering the pump.
Would love to know if I botched anything here and if he had good reason for the suction plumbing running around the planter. He also put a check valve connecting the pool and spa returns. I assume this is to get a little circulation to the spa since it is raised.