What does breathable actually mean in the context of a building?
What does breathable actually mean in the context of a building? Does the building breathe like I do with air coming into my lungs & back out again as carbon dioxide?
No, not exactly.
It means that the building materials can transmit moisture.
Breathable building materials are permeable enough so that any moisture from humid air & moisture from surface wetting can be absorbed & can then easily evaporate during dryer warm periods.
A lot of natural, traditional building materials have inherent properties that allow moisture vapour to pass through them, they are vapour permeable. These materials can also absorb & retain moisture in vapour form [like moist damp air in the background or from a bathroom], this means they are also moisture buffering [the scientific word for this is ‘hygroscopic’].
Another way to describe these 'breathable' building materials is that they are ‘vapour open’ or ‘vapour permeable’.
This is very different from some modern, synthetic building materials that are made from fossil fuels & plastic and are heavily processed. These are the opposite & therefore classified ‘vapour closed’ or ‘non-vapour permeable’. They don’t ‘breathe’.
Here’s a couple of cross section sketches that show how this works in practice.
Sketch 1 illustrates a breathable vapour OPEN construction.
Breathable vapour open buildings mean that background water vapour is intended to enter the constructional build up, it’s not intended to stop it entering. Over the colder, damper winter months, with higher internal humidity, a certain amount of water vapour moisture can enter the build-up & is temporarily stored in the insulation. Then, over the warmer, summer months, when the internal humidity drops, the stored water vapour moisture can evaporate harmlessly into the room.

Sketch 2 illustrates a non-breathable vapour CLOSED construction.
Sealed vapour closed buildings can work but as they rely on internal vapour control membranes that are not vapour permeable, they need extremely good site workmanship [should that be ‘workpersonship’?] to ensure the insulation is fitted tightly without edge gaps and the internal membranes are installed fully sealed without any gaps or holes. In reality it’s likely there will be gaps, as I understand it is impossible to ever build a 100% fully sealed construction.
Nature knows best, who’d have thought it?