TX client bought a new build 6? 7? years ago, lately noticed bad grout & funk smells in primary shower. He's undertaking the demo (I'm on another bathroom). The story: the requested 18×18" bench wasn't>>they told their builder to please do that before move-in>>sub built a bench>>nope, not 18",>>then added onto the "new" bench.
AI says: "Adding a shower bench to an existing finished shower is a complex retrofit that requires breaching the existing waterproofing and tile to ensure structural integrity and prevent leaks. The most reliable method involves carefully removing tiles in the designated area to access the wall studs, allowing for secure anchoring and proper integration of a new waterproof membrane."
I think I can do this; I've done ~40 showers with custom pans, benches, niches, etc. Anyone out there ever bump into something like this and have success reusing/folding up the liner onto a new framed bench or was it a complete re-pan?